Part Number Hot Search : 
222M35 24LC01B MAX232 D5555C 58110 CPH5802 TSOP7000 306PRF
Product Description
Full Text Search
 

To Download CTEM9N01GD0 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
FEATURES * 0...0.35 to 0...35 bar, 0...5 to 0...500 psi gage1 or absolute10 * 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output * Field interchangeable * For industrial use * All welded stainless steel diaphragm construction MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316)9 Housing: stainless steel, protection class IP 64 (according to DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS11,12
Maximum ratings Supply voltage (reverse polarity protection) CTE(M)/CTU9...0 12...32 V CTE(M)/CTU9...1, ...6, ...7 9...32 V CTE(M)/CTU9...42 9...32 V Maximum load current (source) CTE(M)/CTU9...0, ...1, ...6, ...7 Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure CTEM9350... CTU9005... all others
3
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
+Vs 1 Vout 2 -Vs 4 case 3
V
12 (9) to 32 V
sensor
1 mA
GND
-55 to 100C -40 to 100C 0 to 70C 0 - 98 %RH 10 gRMS 50 g
4...20 mA output
+Vs 1 N/C 2 -Vs 4 case 3 9 to 32 V
sensor
V
RL GND
1000 mbar 15 psi 2 x rated pressure
December 2008 / 509
1/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure CTEM9350... CTE9001... CTE9N01... CTE9P01... CTE9002... CTE9003... CTE9005... CTE9010... CTE9016... CTE9020... CTE9035... CTU9005... CTU9015... CTU9N15... CTU9P15 CTU9030... CTU9050... CTU9100... CTU9300... CTU9500... Thermal effects (0 to 70C)4 Thermal effects (-40 to 0C, 70 to 100C) Offset Span Offset Span
Min.
0 0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0
Typ.
Max.
0.35 1 1 0 2 3 5 10 16 20 35 5 15 15 0 30 50 100 300 500
Unit
bar
p si
0.02 0.02 0.03 0.03 0.2 0.1
0.05 0.05
%FSO/C
Non-linearity and hysteresis (BSL)5 Repeatability Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span CTE(M)/CTU9...4 all others CTE(M)/CTU9...4 all others
0.5 %FSO
0.1 0.04 1 0.05 0.002 0.08 0.002 %FSO/V ms
December 2008 / 509
2/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...9N... all others CT...9N... all others 4.9 -0.1 4.9 9.9
Typ.
5 0 5 10 4
Max.
5.1 0.1 5.1 10.1 25 9.5
Unit
V
Output impedance Current consumption (no load)
mA
0.5...4.5 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...9N... all others CT...9N... all others
Min.
2.45 0.45 1.95 3.95
Typ.
2.5 0.5 2 4 4
Max.
2.55 0.55 2.05 4.05 25 8.5
Unit
V
mA
0...5 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...9N... all others CT...9N... all others
Min.
2.45 -0.05 2.45 4.95
Typ.
2.5 0 2.5 5.0 4
Max.
2.55 0.05 2.55 5.05 25 8.5
Unit
V
mA
1...6 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...9N... all others CT...9N... all others 3.45 0.95 2.45 4.95
Typ.
3.5 1 2.5 5.0 4
Max.
3.55 1.05 2.55 5.05 25 8.5
Unit
V
Output impedance Current consumption (no load)
mA
4...20 mA output (VS = 15 V, RL = 100 , tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...9N... all others CT...9N... all others 11.8 3.8 7.8 15.8
Typ.
12.0 4.0 8.0 16.0 260
Max.
12.2 4.2 8.2 16.2
Unit
mA
Power consumption (IL = 20 mA)
December 2008 / 509
mW
3/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
Specification notes:
1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70C relative to 25C. All specifications shown are relative to 25C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Tests are in accordance with EN61000-6-2, April 1999. 9. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also. 10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. 11. CE-labelling is in accordance with 89/336/EEC. 12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
OUTLINE DRAWING
NOM 85.0 (3.35) 6.5 (0.26) 65.0 (2.56) 4 vent hole
21.8 (0.86) diam.
G 1/8" (BSP)
1 3
M12 x 1
2
Detail A
Detail A
Output
Pin 1 2 3 4 0...10 V 0.5...4.5 V 0...5 V, 1...6 V +VS Vout case -Vs
4.0 (0.16) diam.
4...20 mA +VS NC case -Vs
o-ring grove for o-ring 11.8 x 1.8 (0.456 x 0.071) (ZA004029)
mass: 82 g
dimensions in mm (inches)
December 2008 / 509
4/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101: ZP000112-B: Connector/cable assembly (different cable lenghts available) Mating Connector (without cable)
NOM 2 m
(other cable lenghts on request)
PIN CONNECTION Pin Flying lead end Brown Green White and shield Yellow
NOM 60
Shield
1 2 3
36.5
4
Vent tube
M12x1 O 20
Note: For proper function of all gage devices the vent tube must have access to the ambient atmosphere.
dimensions in mm
OPTIONAL PRESSURE FITTINGS (brass, nickel plated)
Male fittings
A B C
LOAD LIMITATION
4...20 mA output version
1400 Ohm 1200
D
1000 800
op e ra ratin ng g e
600
Female fittings
E
G F H
400 200 0 5 9
16 20 25 30 32 V supply voltage
Dimensions in mm (inches) A 1/8" BSPT 1/4" BSPT 3/8" BSPT 1/2" BSPT 1/8" BSP 1/4" BSP 3/8" BSP 1/8" NPT 1/4" NPT B 8 (0.315) 12 (0.472) 11.5 (0.453) 16 (0.630) 12.5 (0.492) 8.5 (0.335) 12.5 (0.492) 10 (0.394) 14 (0.551) C 13 (0.512) 5.5 (0.217) 5 (0.197) 7 (0.276) 11 (0.433) 5 (0.197) 7 (0.276) 13 (0.512) 6 (0.236) D (Hex.) 14 (9/16") 14 (9/18") 17 (11/16") 22 (7/8") 14 (9/16") 19 (3/4") 22 (7/8") 17 (11/16") 22 (7/8")
E 1/8" BSP 1/4" BSP 3/8" BSP 1/2" BSP
Dimensions in mm (inches) F 5 (0.197) 7 (0.276) 6 (0.236) 18 (0.707) G 15 (0.591) 20 (0.787) 20 (0.787) 23 (0.906) H (Hex.) 14 (9/16") 17 (11/16") 22 (7/8") 24 (15/16")
December 2008 / 509
5/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A <1 %FSO electromagnetic field immunity (RFI) 80 % AMC (1 kHz) Electrical fast transient / EN61000-4-4: Grade 3, 2 kV B <1 %FSO burst immunity (EFT) Electrostatic discharge immunity EN61000-4-2: Grade 4, 8 kV, contact discharge B <1 %FSO test (ESD) Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz A <1 %FSO induced by radio-frequency fields 10 V, 80 % AMC (1 kHz)
ORDERING INFORMATION CTx
E: U: bar calibration psi calibration
M
9xxx
x
x
x
Output signal 0: 0...10 V 1: 1...6 V 4: 4...20 mA 6: 0.5...4.5 V 7: 0...5 V
mbar-ranges (only)
CTE9000 series 350: 0 to 350 mbar (gage only) 001: 0 to 1 bar N01: -1 to +1 bar (gage only) P01: -1 to 0 bar (gage only) 002: 0 to 2 bar 003: 0 to 3 bar 005: 0 to 5 bar 010: 0 to 10 bar 016: 0 to 16 bar 020: 0 to 20 bar 035: 0 to 35 bar
CTU9000 series 005: 0 to 5 psi (gage only) 015: 0 to 15 psi N15: -15 to +15 psi (gage only) P15: -15 to 0 psi (gage only) 030: 0 to 30 psi 050: 0 to 50 psi 100: 0 to 100 psi 300: 0 to 300 psi 500: 0 to 500 psi
Fitting size9 D: 1/8" BSPT E: 1/4" BSPT F: 3/8" BSPT G: 1/2" BSPT K: L: M: N: P: Q: R: S: U: V: W: X: Y: 1/8" 1/4" 1/8" 1/4" G G G G G G G G
male, male, male, male,
brass, brass, brass, brass,
nickel nickel nickel nickel
plated plated plated plated
NPT male, brass NPT male, brass NPT male, SS 1.4305 (303) NPT male, SS 1.4305 (303) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) male, male, male, male, brass, brass, brass, brass, nickel nickel nickel nickel plated plated plated plated plated plated plated plated
1/8" 1/4" 3/8" 1/2" 1/8" 1/4" 3/8" 1/2"
Pressure mode G: gage pressure 1 A: absolute pressure
(available for pressure ranges from 1 bar /15 psi absolute upwards only)
female, female, female, female,
brass, brass, brass, brass,
nickel nickel nickel nickel
G 1/8" (BSP) male, SS 1.4404 (316) no optional fitting
Note:
Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. December 2008 / 509 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of CTEM9N01GD0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X